Basic Function PDF Print E-mail
BFS-500A Basic Function Description Intermediate hopper for biomass fiber Double wall exterior panels Heat exchanger tubes Hot air duct to feed into poultry house 5000 CFM blower for cold air return from poultry house Easy Access trays for ash removal (1x per winter flock) Combustion Chamber Variable speed blower to regulated feed of combustion air Variable speed metering auger to regulate feed of biomass fiber

 

 

orange_seperator.jpg

 


 
old_model.png

This older model is of similar design to the BFS-500A.  This furnace as well as another BFS furnace is currenlty being used at a University of Georgia test site in Winteville, GA.  To see the new model click here.

To see the news letters produced by the University of Georgia Poultry Extension go to http://www.poultryventilation.com/ and click on Poultry Housing Tips.